You can monitor UPS devices attached to the hosts via serial cable or USB via UPS subagent. Once you have your UPS attached to the host and NetXMS agent installed, you should configure UPS subagent. First, add the following line to agent's configuration file main section:
American Power Conversion 10-30 KVA User Manual • Serial number, Type label, Introduction – ups family range and components • American Power Conversion Tools. APC Smart-UPS VT 10kVA 208/220V. APC Smart-UPS VT 10kVA 208/220V. How to Find APC UPS Battery Via Serial Number by Peter Hall APC is a leading manufacturer of uninterruptible power supplies for everything from a desktop computer to a data center. Jan 7, 2008 - “An APC tech let me in on a little trick on how to tell if a UPS is within the 2-year warranty period by looking at the serial number. The first two.
Hi Everyone, With the release of 2018.2, APC UPS monitoring is now natively supported. I have been trying to figure out why some of my APC UPS units are Join more than 150,000 members who help IT professionals do their jobs better.
Asmedia 106x sata controller driver win 81. Second, configure attached UPS devices. Create UPS section, and for each UPS device attached to the host add line in the following format:
where id is a number in range 0 . 127 which will be used in requests to identify device; port is a communication port for serial connection or UPS serial number for USB connection; and protocol is a communication protocol used by connected device. Protocol can be either APC (for APC devices), BCMXCP (for devices using BCM/XCP protocol – for example, HP, Compaq, or PowerWare devices), or USB for USB-attached devices. Below is an example of UPS configuration section for two devices attached via serial ports, one is APC device (configured as device 0) and one is HP device (configured as device 1):
Once UPS subagent is configured, you can start to monitor UPS devices status via parameters provided by it:
Please note that not all parameters supported by all UPS devices. Many old or simple models will support only basic things like UPS.OnlineStatus parameter.Most tipical approach is to monitor UPS.OnlineStatus for going to 1 or 2, and then send notifications to administrators and shutdown affected hosts if needed. You can also monitor UPS.EstimatedRuntime parameter for the same purposes if your devices support it.
Consider the following simple scenario: you have two servers, Node_A and Node_B, connected to one UPS device. UPS device is APC Smart UPS 1700, connected with serial cable to Node_A on first COM port. Both nodes are running Windows operating system. You need to notify administrator if UPS goes to battery power, and shutdown both nodes in case of low battery condition. We assume that both nodes have NetXMS agent installed.To accomplish this, do the following:
Step 1.
Configure UPS monitoring subagent on Node_A. Add the following line to main agent's config section: Back in black free download.
Apc Ups Serial Number Lookup
At the end of configuration file, create UPS subagent configuration section:
Retrieved from 'https://wiki.netxms.org/index.php?title=Uninterruptible_Power_Supply_(UPS)_Monitoring&oldid=1102'
Serial Number Lookup SpecsIssue:The UPS indicates battery replacement is required or is providing insufficient runtime compared to when the UPS was first put into service. Product Line: Smart-UPS and Back-UPS Environment: All models, All Serial Numbers Cause: Battery replacement is part of the normal maintenance for your UPS. Resolution: To determine the correct Replacement Battery Cartridge to purchase for your APC UPS and to see other options available to you, use the UPS Replacement Battery Selector tool on www.apc.com. Before you use this tool, you will need to know your UPS model #. To find your UPS model #, locate a white bar-code sticker on your UPS. This can be found behind or on the bottom of your UPS. The bar code label will look similar to the one below: The top row of the bar code sticker indicates the UPS model number. The bottom row indicates the UPS serial number. The first two numbers in the serial number indicate the year that the UPS was manufactured. For example, serial #SB04 Apc Smart Ups Serial Number Lookup1650513 is a unit manufactured in 2004. The age of the UPS will also help you to determine if you need a replacement battery cartridge. A battery will typically last 3-5 years, varying based on frequency of use, duration of use and environmental conditions such as heat and humidity.Now that you've acquired your model, go to APC's convenient, easy-to-use UPS Replacement Battery Selector tool. You can simply enter your model # and the Selector will provide you with the available options for upgrading your ups, or purchasing a replacement battery cartridge (RBC). Apc Serial Number CheckIf you purchase a Replacement Battery cartridge (RBC) please note that some units contain multiple batteries inside the UPS. The Selector will provide you with a single part # that will contain all the batteries you will need for your UPS model, unless otherwise indicated in the chart. Serial Number Lookup For GunsFor example, a model SU700NET has 2 batteries inside. If you purchase qty 1 #RBC5, you will receive a cartridge containing the 2 batteries needed for your unit, hence you only need to purchase one part #RBC5 for your SU700NET.Comments are closed.
|
Details
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |